This product amplifies signals from Load Cells to measure forces in the Structures Systems and is compatible with PASPORT Interfaces.
- 1x PASPORT Load Cell Amplifier (PS-2198)
- 1x Instruction manual
See the Buying Guide for this item's required, recommended, and additional accessories.
Product Summary
This Load Cell Amplifier can accommodate up to six load cells and utilizes a single PASCO interface port to connect to a computer's USB port. Students can insert up to six load cells at various points of their structures to extensively analyze their bridges. The Amplifier is compatible with both 5 and 100 N Load Cells, and features a maximum data sampling rate of 500 Hz per port.
What's Included
- 1x PASPORT Load Cell Amplifier (PS-2198)
- 1x Instruction manual
Product Specifications
Load Cell Ports | 6 |
Accuracy | ± 1% |
Resolution | 0.003 N |
Maximum Sample Rate | 500 Hz |
Differential input voltage for any load cell | ± 9.96 mV |
Measurement Ranges | ± 100 N or ± 5 N depending on load cell selected |
Data Collection Software
This product requires PASCO software for data collection and analysis. We recommend the following option(s). For more information on which is right for your classroom, see our Software Comparison: SPARKvue vs. Capstone »
Interface Required
This product requires a PASCO Interface to connect to your computer or device. We recommend the following option(s). For a breakdown of features, capabilities, and additional options, see our Interface Comparison Guide »
Dedicated Datalogging with SPARK LXi2
Consider an all-in-one, touchscreen data collection, graphing, and analysis tool for students. Designed for use with wired and wireless sensors, the SPARK LXi2 Datalogger simultaneously accommodates up to five wireless sensors and includes two ports for blue PASPORT sensors. It features an interactive, icon-based user interface within a shock-absorbing case and arrives packaged with SPARKvue, MatchGraph!, and Spectrometry software for interactive data collection and analysis. It can additionally connect via Bluetooth to the following interfaces: AirLink, SPARKlink Air, and 550 Universal Interface.
Buying Guide
Required Accessories | P/N | Price |
---|---|---|
1x 100 N Load Cell | PS-2200 | -- |
1x 5 N Load Cell | PS-2201 | -- |
Also Available | P/N | Price |
---|---|---|
Load Cell and Amplifier Set | PS-2199 | -- |
Product Guides & Articles
PASCO Structures System
PASCO’s Structures System offers realistic, hands-on tools for students to design and create life-like structures in the classroom. Intended for teaching principles of engineering and mechanical design, these systems are ideal for civil and mechanical engineering education courses. Materials range in complexity from single trusses to dynamic kits for design-based experimentation. This guide explains and compares all of our Structure System options and accessories.